GE Multilin L60 Line Phase Comparison System

$1.00

The L60 provides fast and secure sub-cycle phase comparison protection, for both two-terminal and three-terminal lines, lines with series compensation and for single-pole and three-pole tripping applications. The L60 can operate using existing power line carrier or fiber optic communications, and compensates for channel asymmetry and charging currents. The L60 can provide complete support of dual-breaker line terminals by using multiple current inputs.

Key Benefits:

  • Extremely fast and secure phase comparison protection with a typical tripping time of ¾ power cycle
  • End-to-end communication over power line carrier provides cost-effective solution
  • Advanced IEC 61850 Ed. 1 and Ed. 2 certified implementation, complete settings via SCL files and flexible process bus support (IEC 61850-9-2LE or IEC 61850-9-2 Hardfiber) ensures interoperability, device managing optimization and reduced cost of ownership
  • Routable GOOSE (R-GOOSE) enables GOOSE messages going beyond the substation, which enables wide area protection and control applications
  • Robust network security enabling Critical Infrastructure Protection through user command logging, and dual permission access control
  • Three-zone high-speed backup phase and ground distance function
  • Advanced fault and disturbance recording, including internal relay operating signals, eliminating the need for external recording devices
  • Application flexibility – multiple I/O options, programmable logic (FlexLogic™), modularity, customizable to specific requirements
  • Embedded IEC61850 protocol
  • Application flexibility with multiple I/O options including high density I/O, programmable logic, modularity, and specific customization
  • An integrated large, full color display, provides real-time visualization and control of the protected bay, via a bay mimic as well as annunciator functionality and graphical visualization of phasors
Get A Quote On This Product For Your Project

Description


Key Features:

  • Breaker condition monitoring including breaker arcing current (I2t) and trip counter
  • Metering – current, voltage, power, energy and frequency
  • Oscillography – 64 samples/cycle, up to 64 records
  • Event Recorder – 1024 time tagged events, with 0.5ms scan of digital inputs
  • Data Logger- Up to 16 channels with user-selectable sampling rate
  • Fault Locator

 

Interoperability with embedded IEC 61850

Use the L60 with integrated IEC 61850 to lower costs associated with protection, control and automation. GE’s leadership in IEC 61850 comes from thousands of installed devices and follows on years of development experience with UCA 2.0.  The L60’s IEC 61850 Process Bus module is designed to interface with the Multilin HardFiber System, allowing bi-directional IEC 61850 fiber optic communications. The HardFiber System is designed to integrate seamlessly with existing Universal Relay applications, including protection functions, FlexLogic, metering and communications.

 

Applications:

  • Short and long overhead lines and cables of different voltage levels
  • Suitable for two- and three-terminal lines
  • Circuits with tapped transformer feeders
  • Implicit direct transfer trip for breaker failure applications

Communications:

  • Three independent 100Mbps Ethernet ports enable purpose specific LAN support that eliminates latency effect of heavy traffic protocols on mission critical communication services
  • Embedded IEEE 1588 time synch protocol support eliminates dedicated IRIG-B wiring requirements for IEDs
  • Direct I/O secures high-speed exchange of binary data between URs
  • Increase network availability by reducing failover time to zero through IEC62439-3 “PRP” support
  • IEC 61850-9-2LE networked or IEC61850-9-2 Hardfiber process bus support
  • DNP 3.0 (serial & TCP/IP)
  • IEC 60870-5-103 and IEC 60870-5-104
  • Modbus RTU, Modbus TCP/IP
  • HTTP, TFTP, SFTP and MMS file transfer
  • Redundant SNTP and IEEE 1588 for time synchronization
  • PRP as per IEC 62439-3
  • Supports Routable GOOSE (R-GOOSE)

 

UR Switch Module:

In addition to providing high-speed connectivity directly to your Universal Relay, the UR Switch Module provides an additional 4 fiber Ethernet ports, for connection to other relays in the system as well as upstream connectivity. It also provides 2 RJ45 copper Ethernet ports which can be used to connect local devices such as PCs, meters, or virtually anything else in the system.

The UR Switch Module provides a simple way to add fully-managed Ethernet networking to your relays and devices without the need for additional hardware or a dedicated communications cabinet.

The UR Switch Module includes all of the management and features that come with all MultiLink managed switches, and can be easily integrated into a network that has other Ethernet switches.

When used in a ring topology with other UR Switch Modules or MultiLink Switches, the UR Switch Module can be configured to use MultiLink’s Smart RSTP feature to provide industry-leading network recovery for ring topologies, at a speed of less than 5ms per switch.