GE Multilin D60 – Line Distance Protection System

$1.00

The D60 is suitable for protecting transmission lines and cables including lines equipped with series compensation. The D60 supports dual-breaker applications and can be applied in single-pole or three-pole tripping applications. The D60 is applicable to different teleprotection schemes and includes inter-relay protection communications via direct fiber as well as different interfaces. The D60 also provides synchrophasor measurement over Ethernet per IEEE C37.118.

  • Five zone quad or mho, phase and ground distance protection
  • Advanced IEC 61850 Ed. 1 and Ed. 2 certified implementation, complete settings via SCL files and flexible process bus support (IEC 61850-9-2LE or IEC 61850-9-2 Hardfiber) ensures interoperability, device managing optimization and reduced cost of ownership
  • Routable GOOSE (R-GOOSE) enables GOOSE messages going beyond the substation, which enables wide area protection and control applications
  • Reliable and secure protection on series-compensated lines
  • Superior phase selection algorithm
  • Supports multiple standard pilot schemes
  • Flexible programmable logic for building customized schemes
  • Simplified teleprotection interfaces with direct I/O communications
  • Robust network security enabling Critical Infrastructure Protection
  • Phasor Measurement Unit (synchrophasor) according to IEEE® C37.118 (2011) and IEC® 61850-90-5 support
  • Application flexibility with multiple I/O options including high density I/O, programmable logic, modularity, and specific customization
  • An integrated large, full color display, provides real-time visualization and control of the protected bay, via a bay mimic as well as annunciator functionality and graphical visualization of phasors
Get A Quote On This Product For Your Project

Description


Applications:

  • Overhead lines including series-compensated lines and underground cables
  • Single and dual-breaker circuits requiring single pole/three-pole auto-reclosing
  • Circuits with in-zone power transformers
  • Secure application with CCVTs backup protection for generators, transformers and reactors

 

Protection & Control:

  • Expanded Bay Controller Capabilities – providing a one box solution
  • Added backup protection functions with sensitive reverse power element “32S”
  • Added over/under/rate of change of frequency elements
  • New thermal overload element
  • New broken conductor element
  • Customizable version of the POTT and DCB schemes “POTT1 and DCB1”
  • Neutral directional overcurrent with dual polarity criteria “67N”

 

Cyber Security:

  • Password Complexity
  • AAA Server Support (Radius)
  • Role Based Access Control (RBAC)
  • Event Recorder (Syslog for SEM)

Enhanced Communications:

  • New UR process bus modules supporting IEC61850-9-2LE Merging Units and IEC61850-9-2 Hardfiber
  • Support switchable IEC 61850 Ed. 1 and Ed. 2 and redundant SNTP
  • New UR front panel with integrated 7” color, graphical display – providing operators with enhanced situational awareness
  • Routable GOOSE (R-GOOSE) enables GOOSE messages going beyond the substation, which enables wide area protection and control applications
  • Increases GOOSE message reception up to 64 remote devices
  • IEC 61850 in line with Edition 2, IEC 61850 SCL file for all relay’s setting
  • IRC module that combines C37.92 multimode and direct connection singlemode
  • Three independent Ethernet ports
  • Time synchronization via IEEE 1588
  • PRP as per IEC 62439-3
  • IEC 60870-5-103

 

EnerVista™ Software

The EnerVista™ suite is an industry-leading set of software programs that simplifies every aspect of using the D60 relay. The EnerVista™ suite provides all the tools to monitor the status of the protected asset, maintain the relay, and integrate information measured by the D60 into DCS or SCADA monitoring systems. Convenient COMTRADE and Sequence of Events viewers are an integral part of the UR setup software included with every UR relay, to carry out postmortem event analysis and ensure proper protection system operation.