GE Multilin C60 – Substation Hardened for Protection & Control of Circuit Breakers

$1.00

The C60 breaker protection system is a substation hardened controller that provides a complete integrated package for the protection, control, and monitoring of circuit breakers. The C60 supports dual-breaker busbar configurations such as breaker-and-a-half or ring bus arrangements.Signals from up to 4 sets of CT’s can be brought into the C60 via conventional wiring or process bus for internal summation, which is advantageous by still having the individual currents available for metering and the additional protection elements that operate on individual currents.

  • Complete breaker control, monitoring and integration in a single platform
  • Advanced IEC 61850 Ed. 1 and Ed. 2 certified implementation, complete settings via SCL files and flexible process bus support (IEC 61850-9-2LE or IEC 61850-9-2 Hardfiber) ensures interoperability, device managing optimization and reduced cost of ownership
  • Routable GOOSE (R-GOOSE) enables GOOSE messages going beyond the substation, which enables wide area protection and control applications
  • Reduced wiring through the use of high-speed peer-to-peer communication for accepting trip and close commands from other relays
  • Advanced automation capabilities for providing customized protection and control solutions
  • Robust network security enabling Critical Infrastructure Protection through user command logging, and dual permission access control
  • Simplified system integration with communications supporting serial, Ethernet and multiple protocols
  • Phasor Measurement Unit (synchrophasor) according to IEEE® C37.118 (2011) and IEC® 61850-90-5 support
  • Supports latest edition of waveform capture (COMTRADE 2013) simplifying fault records management
  • Application flexibility with multiple I/O options including high density I/O, programmable logic, modularity, and specific customization
  • An integrated large, full color display, provides real-time visualization and control of the protected bay, via a bay mimic as well as annunciator functionality and graphical visualization of phasors
Get A Quote On This Product For Your Project

Description


New and Enhanced Communication:

  • New UR process bus modules supporting IEC61850-9-2LE Merging Units and IEC61850-9-2 Hardfiber
  • Support switchable IEC 61850 Ed. 1 and Ed. 2 and redundant SNTP
  • New UR front panel with integrated 7” color, graphical display – providing operators with enhanced situational awareness
  • High density I/O module supporting up to 120 inputs or up to 72 contact outputs – eliminating the need for additional discrete devices
  • Increases GOOSE message reception up to 64 remote devices
  • R-GOOSE enables GOOSE messages going beyond the substation, which enables wide area protection and control applications
  • IEC 61850 in line with Edition 2, IEC 61850 SCL file for all relay’s setting
  • IRC module that combines C37.92 multi mode and direct connection single mode
  • Three independent Ethernet ports
  • Time synchronization via IEEE 1588
  • PRP as per IEC 62439-3
  • IEC 60870-5-103

Applications:

  • Stand-alone breaker monitoring and control
  • Multiple breaker configuration control including breaker-and-a-half and ring bus
  • Automatic bus transfer scheme using a single device
  • As part of a distributed bay controller

Cyber Security – CyberSentry™ UR

CyberSentry enables UR devices to deliver full cyber security features that help customers to comply with NERC CIP and NITIR 7628 cyber security requirements through supporting the following core features:

  • Password Complexity
  • AAA Server Support (Radius)
  • Role Based Access Control (RBAC)
  • Event Recorder (Syslog for SEM)

 

New and Enhanced Protection and Control Functionality

  • Expanded Bay Controller Capabilities – providing a one box solution

 

Fully Compatible with GE’s Multlilin HardFiber System – Provides support for GE’s IEC 61850 HardFiber Process Bus Solution:

  • Complete IEC 61850 Process Bus Solution providing resource optimization and minimizing total P&C life cycle costs

 

Extended Oscillography Records

  • Supports IEEE C37.111-1999/2013, IEC 60255-24 Ed 2.0 COMTRADE 2013 standard
  • Added open pole detector functionality
  • Added phase overvoltage protection
  • New thermal overload element