Description
- Comprehensive metering & power-up diagnostics
- Two stage circuit breaker failure and breaker condition monitoring
- Switchgear supervision including CT/VT, DC supply, full Trip Circuit Supervision, CB failure
- Switch control and status (up to 8) and up to 2048 events and 10.5 s disturbance records
Metering, Monitoring & Diagnostics
All events, fault and disturbance records are time tagged to a resolution of 1 ms. Up to 2048 time-tagged event records are stored in the flash memory and can be extracted using the communication ports or viewed on the front panel display.
Records of the last 10 faults are stored in the flash memory. Fault data is also available via IEC 61850 protocol. The internal disturbance recorder has up to 9 analogue channels, 64 digital channels and 1 time channel. The memory capacity is approx. 50 records for a typical 0.5 s duration.
The measurements provided, which may be viewed in primary or secondary values, can be accessed via the front panel LCD display, or the communications ports. Measurements are available in P14D for easy retrofit of KMPC130 devices.
P40 Agile can be used to monitor the integrity of the breaker coils and circuits with support for various TCS schemes.
Download Further Product Information Here
All events, fault and disturbance records are time tagged to a resolution of 1 ms. Up to 2048 time-tagged event records are stored in the flash memory and can be extracted using the communication ports or viewed on the front panel display.
Records of the last 10 faults are stored in the flash memory. Fault data is also available via IEC 61850 protocol. The internal disturbance recorder has up to 9 analogue channels, 64 digital channels and 1 time channel. The memory capacity is approx. 50 records for a typical 0.5 s duration.
The measurements provided, which may be viewed in primary or secondary values, can be accessed via the front panel LCD display, or the communications ports. Measurements are available in P14D for easy retrofit of KMPC130 devices.
P40 Agile can be used to monitor the integrity of the breaker coils and circuits with support for various TCS schemes.
- Comprehensive metering & power-up diagnostics
- Two stage circuit breaker failure and breaker condition monitoring
- Switchgear supervision including CT/VT, DC supply, full Trip Circuit Supervision, CB failure
- Switch control and status (up to 8) and up to 2048 events and 10.5 s disturbance records
GE MiCOM Agile P14x Guideform Specifications